Wiring the system
Caution: Always power-down the panel
when wiring external circuits, to prevent
damage to the panel electronics.
Systematically wire and test each circuits.:
ÿ
Zone, Tamper circuit and PA circuits
ÿ
Finish by wiring any additional extension
speaker sounders, external bell/sounder,
strobe and the 13V supply.
Tamper network
The Tamper circuit is used to protect all cables
and detectors in the system from unauthorised
access including the panel and RKP covers.
The zone and PA tampers should be series wired
and connected to the TAMP terminals.
TerminalsT&Aarefortheexternal bell /
sounder tamper. The TAMP terminals at the
bottom left of the PCB are for the RKP tampers.
Tamper alarms that occur in the Day mode
operate internal sounders only. Tamper alarms in
Set cause a full alarm condition. Tamper is
indicated on the control panel and RKPs by the
Tamper indicator.
Connect Remote Keypads /
Lighting controllers
Note: Where an Accenta G3 or Accenta
mini G3 panel is being installed ensure
there is at least one remote keypad wired
to the panel before first power up.
A combination of up to four remote keypads and
lighting controller can be connected to the panel.
Security zones
Note: The G3 range of panels are not
supplied with wire links for unused
zones. All unused zones must be
programmed out by setting them to
disabled using the Zone Type function
see page 19.
It is recommended that no more than 10
magnetic contacts are connected to the same
zone.
4PI175 issue 1_6/01 5
Accenta/Optima G3 intruder system Engineering information
Wiring the system
J5
0V
TAMP
+13V
COMMS
SOUND
1A
RKP FUSE
F2
Panel
Board
SOUND
TAMP
COMMS
13V
0V
Keypad
Board
COMMS
12V
SOUND
LD R
Maximum of up to 4 Remote Keypad /
OPTI-CAM Lighting Controller
combination allowed
Board
SOUND
TAMP
COMMS
13V
0V
Keypad
Board
GND
OPTI-CAM Lighting
Controller
(See also the instructions supplied
with the OPTI CAM lighting controller)
If only one Remote keypad
is being used then connect TAMP
back to the
anel
J2
2
1
4
3
6
5
8
7
Panel
Alarm
+-
PA
+
-
TAMP
+13V 0V
PIR
Unused zones must
be programmed as
Unused.
Board
PIR
Door
Contact
Door
Contact
Terminal block
is not supplied
Tamp