Accenta/Optima Engineer’s Manual
18
Menu Options
The full menu structure for the panel can only be accessed while in Engineer program mode. The structure is
shown in the following table:
Table 2. Menu Options
Menu Options
MENU OPTIONS
0 = Walk Test 7 = Timers
1 = Alarm Test 8 = Codes
2 = Test Outputs C = View Event Log
3 = System Flags O = Omit Allow & Double Knock
4 = Time and Date P = Set up Programs
6 = Zone Names
Enter Engineer program mode. Press [PROG] [9] [9] [9] [9].
0 = Walk Test
The walk test function allows each detector to be checked in order to verify that they are functioning correctly.
A tone is generated as each zone is activated (opened).
LED keypad
Press [0] for menu Walk Test.
Press [SET]. Zones 1-8 are off
When a zone is sucsessfully tested, the LED is on.
Zones are added to list as each one is activated.
The Tamper LED comes on when tested.
Press [RESET] to leave the menu or [SET] to restart
the Walk Test.
LCD keypad
Press [up arrow] for menu Walk Test.
Press [SET] or [0]. Zones 1-8 have a zero (0)
below each number.
When a zone is sucsessfully tested, number 1
replaces the 0. Zones are added to list as each
one is activated.
Press [RESET] to leave the menu or [SET] to
restart the Walk Test.
0>Walk Test0>Walk Test
0>Walk Test0>Walk Test
0>Walk Test
[up arrow]
[SET] or [0]
[RESET]
0>Walk Test0>Walk Test
0>Walk Test0>Walk Test
0>Walk Test
12345678 TP12345678 TP
12345678 TP12345678 TP
12345678 TP
00000000 0000000000 00
00000000 0000000000 00
00000000 00
12
3
4
5
6
7
8
[SET]
12
3
4
5
6
7
8
[RESET]