Accenta/Optima Engineer’s Manual
4
PCB
There are four fuses mounted on the circuit board, all are 20mm anti-surge.
F1 1.6A - to protect the positive (+Ve) line of 12V battery
F2 1A - to protect the Speaker 13V supply
F3 1A - to protect the Siren (Bell) & Strobe supply
F4 1A - to protect the RKP 13V supply
As supplied, wire links are fitted across the PA and Tamper terminals to represent a closed circuit.
Wiring the System
CAUTION: Always power down the panel when wiring external circuits to prevent damage to
the panel electronics.
Systematically wire and test each circuit:
Zone, Tamper circuit and PA circuits
Finish by wiring any additional extension speaker sounders, external siren (bell) / strobe and the 13V
supply.
Tamper Network
The Tamper circuit is used to protect all cables and detectors in the system from unauthorised access including
the panel and RKP covers.
The zone and PA tampers should be series wired and connected to the TAMP terminals. Terminals T and A
are for the external siren tamper. The TAMP terminals at the bottom left of the board are for the RKP
tampers.
Tamper alarms that occur in the Day mode operate internal sounders only. Tamper alarms in Set cause a full
alarm condition. Tamper is indicated on the control panel and RKPs.
Figure 4. PCB
PCB